Calculate an example as follows. A 120-volt motor has a load amperage of 5 amps. Multiply 120 volts times 5 amps this equals 600VA now lets multiply the 125 percent start factor. Take 600 times 1.25 this equals 720VA and most transformers are sized by a factor of 25VA or 50VA.
Since you know kVA = V * l / 1,000, we can solve for V to get V = kVA * 1,000 / l. So youll multiply your kVA rating by 1,000 and then divide by the amperage. If your transformer has a kVA rating of 75 and your amperage is 312.5, youll plug those numbers into the equation — 75 * 1,000 / 312.5 = 240 volts.
Step 1: Determine the KVA, Amperes or wattage required by the load. Determine the KVA, Amperes or wattage required by the load. Step 2: Find out the supply voltage. Step 3: Determine the voltage required by the load. Step 4: What is the frequency of the supply source? Step 5: Determine the Marcus transformer model number.
Primary Current (current on High Voltage side) is 5.25 amps. KVA = (√3. V x I) /1000= (1.732 × 11000 × 5.25)/1000=100 KVA .Transformer selection is based on mainly 4 parameters:Power rating in KVA (Kilo Volt Amperes),Primary voltage,Secondary voltage,Tap arrangement.
Industry standard sizes for 480- to 120/208-volt wye transformers are commonly 15, 30, 45, 75, 112.5, 225, 300 and 500 kilovolt-amperes. There are also single-phase 277-or 480-volt transformer sizes available at 5, 7.5, 10, 15, 25, 37.5, 50, 75 and 100 kilovolt-amperes.
The transformer turns ratio is the number of turns of the primary winding divided by the number of turns of the secondary coil. The transformer turns ratio provides the expected operation of the transformer and the corresponding voltage required on the secondary winding.
For a 200 A at 120 V single-phase service, the apparent power is 48 kVA. A 50 kVA transformer wont be installed by the utility. Standard sizes of single phase transformers are 5, 10, 15, 25, 37.5, 50, 75, 100, and so on.
How many kVA is 200 amps?
Generator KVA Rating to Amperage Conversion Chart 80% POWER FACTORkV•AkW208V18715052021917560825020069433 more rows
kVA to Amps Conversion ChartkVAkW240 V1,563 kVA1,250 kW3,760 A1,875 kVA1,500 kW4,511 A2,188 kVA1,750 kW5,264 A2,500 kVA2,000 kW6,014 A28 more rows
3 Answers. Question 1: Every house has separate transformer? No. One pole transformer handles about 200 kVA and typically serves about 5 to 10 homes.
Vp=−NpΔΦΔt V p = − N p Δ Φ Δ t . This is known as the transformer equation, and it simply states that the ratio of the secondary to primary voltages in a transformer equals the ratio of the number of loops in their coils.
In other words, one coil turn on the secondary to one coil turn on the primary. If the output secondary voltage is to be greater or higher than the input voltage, (step-up transformer) then there must be more turns on the secondary giving a turns ratio of 1:N (1-to-N), where N represents the turns ratio number.
Calculate an example as follows. A 120-volt motor has a load amperage of 5 amps. Multiply 120 volts times 5 amps this equals 600VA now lets multiply the 125 percent start factor. Take 600 times 1.25 this equals 720VA and most transformers are sized by a factor of 25VA or 50VA.
Three Phase TransformerKVA208V240V37.510490.345125108501391206016714517 more rows
Three Phase TransformerKVA208V480V2056.624.12569.530.13083.436.137.510445.217 more rows
How many amps is 1kVA?
1,000 Volt 1 kVA is a frequently used unit; it represents 1,000 Volt-Amperes. In many cases, its useful to convert kVA to amps .kVA To Amps Calculator (With Table)kVA (Apparent Power)Voltage (220 V)Amperage (A)How many amps is 1 kVA?220 V4.55 AmpsHow many amps is 5 kVA?220 V22.73 Amps7 more rows•Oct 22, 2020
150 KVA @ 480 3Ø = 180 amps. You can feed it with a 200 but if its loaded to the gills, itll push the 200 a bit. 150 KVA @ 120/208 3Ø = 416 amps.
Generally, a transformer located near a building requires 4ft clearance from the building vertical surfaces, assuming no windows from grade to 18ft.
For a domestic consumer, the range can be wide enough and have 50 consumers connected to a single transformer. while for industrial & commercial consumers with high load , it can be as low as 4-5 consumers.